與靜態傳遞箱相比,在相同的內部尺寸下,它具有更大的外部尺寸和更高的製造成本。 動態傳遞箱分為兩個子類型:層流傳遞箱,它在頂部供應中提供垂直層流
A dynamic pass box ; 指內部氣流動態的傳遞箱,具有自迴圈氣流模式。 將清潔空氣供應到腔室中,同時排出污染空氣,保持傳遞箱內的清潔。
The dynamic pass box is equipped with a fan and a filter. The fan draws air in, and the filter purifies the air before blowing it into the pass box, pushing contaminated air out through the exhaust port, thus creating a continuous circulation.
Compared to a static pass box, the dynamic pass box includes an additional air filtration process and components that provide self-circulating airflow. Therefore, for the same internal dimensions, the external dimensions of a dynamic pass box are larger, and its manufacturing cost is higher than that of a static pass box.
動態傳遞箱可進一步分為;層流通過箱 and air shower pass boxes.
A laminar flow pass box provides vertical laminar airflow. From top to bottom, the pass box is sequentially equipped with a fan, a filter, and a flow straightener (perforated plate/flow homogenizing film). The internal airflow follows a top-supply, bottom-return pattern. The airflow velocity from the flow straightener meets laminar flow requirements.
Unlike the laminar flow type, the air shower pass box is not equipped with a flow straightener. Instead, it features circular nozzles at the air outlet. During operation, clean air filtered by the HEPA filter is blown out from the nozzles at a velocity of no less than 25 m/s ; (典型值),清除被轉移物品表面的灰塵顆粒。 然後,去除的污染物通過出氣口排出或再迴圈到進氣口,再次過濾,並通過噴嘴吹出。 此迴圈形成一個;micro self-circulating clean environment.
電子聯鎖在門打開時提供音訊/視覺警報,防止强行打開造成的意外損壞,啟用BMS集成,並支持用戶數據記錄的存取控制。
使用全焊接不銹鋼結構,具有連續的焊縫和光滑的圓角。 這消除了難以清潔的裂縫和可能積聚污染物的縫隙。
當門關閉時,檢查EPDM或矽膠墊片是否壓縮250%。 如果硬化、破裂或失去彈性,請更換。 用70%酒精清洗; 避免使用會引起腐蝕的氯或強酸清潔劑。
遵循“先清潔,後消毒”的原則-移除外包裝,用70%异丙醇或0.5%過乙酸擦拭,放置時物品之間留有間距,並暴露在紫外線下至少15分鐘(建議30分鐘)。
是的。 USP 797要求對所有分類區域進行表面取樣,包括通過室。 1/2類CSP要求每月取樣; 第3類要求每週取樣和批次末取樣。
指定更乾淨的連接空間的ISO分類。 例如,如果直通將ISO 8連接到ISO 7,則將其歸類為ISO 7。 行業最佳實踐遵循這兩個連接領域的更高標準。
直通室是安裝在潔淨室牆上的外殼,用於促進區域之間的資料轉移,同時最大限度地降低污染風險。 它减少了人流量,保持了壓差,並防止了未經過濾的空氣通過聯鎖門交換。